| Sign In | Join Free | My bjjsgy.com | 
 | 
Brand Name : SOROTEC
Model Number : REVO VP/VM
Certification : CE,ROHS,ISO9000
Place of Origin : China
MOQ : 500PCS
Payment Terms : L/C , T/T
Supply Ability : 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS
Delivery Time : Within 15-30days after receiving your 30% TT deposit
Packaging Details : Packaging Details Carton, export type packing or according to your requirement
Price : $199-$460/Piece
Solar Energy Storage Inverter REVO VP/VM series Built-in MPPT/PWM Solar Controller
Key Features:


| MODEL | REVO VP 1000-12 | REVO VM 1200-12 | REVO VP 2000-24 | REVO VM 2200-24 | REVO VP 3000-24 | REVO VM 3200-24 | REVO VP 5000-48 | REVO VM 5000-48 | 
| Rated Power | 1000VA/1000W | 1200VA/1200W | 2000VA/2000W | 2200VA/2200W | 3000VA / 3000W | 3200VA / 3200W | 5000VA / 5000W | |
| INPUT | ||||||||
| Voltage | 230 VAC | |||||||
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances) | |||||||
| Frequency Range | 50 Hz/60 Hz (Auto sensing) | |||||||
| OUTPUT | ||||||||
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | |||||||
| Surge Power | 2000VA | 4000VA | 6000VA | 10000VA | ||||
| Efficiency(Peak) | 90% ~ 93% | |||||||
| Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) | |||||||
| Waveform | Pure sine wave | |||||||
| BATTERY | ||||||||
| Battery Voltage | 12 VDC | 24 VDC | 48 VDC | |||||
| Floating Charge Voltage | 13.5 VDC | 27 VDC | 54 VDC | |||||
| Overcharge Protection | 16 VDC | 31 VDC | 33 VDC | 63 VDC | ||||
| SOLAR CHARGER & AC CHARGER | ||||||||
| Solar Charger type | PWM | MPPT | PWM | MPPT | PWM | MPPT | PWM | MPPT | 
| Maximum PV Array Open Circuit Voltage | 55 VDC | 102 VDC | 80 VDC | 102 VDC | 80 VDC | 102 VDC | 105 VDC | 145 VDC | 
| Maximum PV Array Power | 600 W | 700W | 1200 W | 1400 W | 1200 W | 1800 W | 2400 W | 3000 W | 
| MPP Range @ Operating Voltage | N/A | 17 ~ 80 VDC | N/A | 30 ~ 80 VDC | N/A | 30~80 VDC | N/A | 60~115 VDC | 
| Maxmum Solar Charge Current | 50 A | 50 A | 50 A | 50 A | 50 A | 65 A | 50 A | 65 A | 
| Maximum AC Charge Current | 20 A | 20 A | 20 A | 20 A | 25A | 25A | 60 A | 60 A | 
| Maximum Charge Current | 50 A | 60 A | 50 A | 60 A | 70 A | 60 A | 110 A | 120 A | 
| PHYSICAL | ||||||||
| Dimension, D x W x H (mm) | 88 x 225 x 320 | 103 x 225 x 320 | 88 x 225 x 320 | 103 x 245 x 320 | 100 x 285 x 334 | 118.3 x 285 x 360.4 | 100 x 300 x 440 | 100 x 302 x 440 | 
| Net Weight (kgs) | 4.4 | 4.4 | 5 | 5 | 6.3 | 6.5 | 8.5 | 9.7 | 
| Communication Interface | USB/RS232 | |||||||
| ENVIRONMENT | ||||||||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |||||||
| Operating Temperature | -10°C to 50°C | |||||||
| Storage Temperature | -15°C to 60°C | |||||||
| THREE STRATEGIC INDUSTRIES | 

| APPLICATION OF OUR PRODUCT | 

1. Living house and home building.
2. Office building, factory and warehouse.
3. Shopping mall, stadium and so on.
4. Power station, field operation and some huge engineer construction.
5. Suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip.
| FACTORY SHOW | 


| COMPANY SHOW | 
Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
| TRADE SHOW | 

| WHY CHOOSE US ? | 
1,QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2,Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
| CERTIFICATIONS | 

| OUR MARKET | 

| PACKAGING | 

| FAQ | 
1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.
.......................................................................................................................................................................................................................................
2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
........................................................................................................................................................................................................................................
3.How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.
.....................................................................................................................................................................................................................................
4.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................................................................................
| CONTACT US | 

|   | 
| high quality Solar Energy Storage Inverter revo vp/vm series Built-in MPPT/PWM Solar Controller Images | 
 Large LCD Online UPS HP9316C 10-20KVA
                                                                                    
                        
                        
                        
                                                            Large LCD Online UPS HP9316C 10-20KVA
                                                    
                        
                     1ph in / out 60Hz 2A 110V UPS HP9116B Series 6KVA / 4800W, 10KVA / 8000W
                                                                                    
                        
                        
                        
                                                            1ph in / out 60Hz 2A 110V UPS HP9116B Series 6KVA / 4800W, 10KVA / 8000W
                                                    
                        
                     RS232 interface 0.7 1ph in / out 110V UPS 10KVA / 8000W with bypass repair
                                                                                    
                        
                        
                        
                                                            RS232 interface 0.7 1ph in / out 110V UPS 10KVA / 8000W with bypass repair
                                                    
                        
                     Three Phase 380V AC 20, 40, 80 KVA High Frequency online UPS with RS232, AS400,
                                                                                    
                        
                        
                        
                                                            Three Phase 380V AC 20, 40, 80 KVA High Frequency online UPS with RS232, AS400,
                                                    
                        
                     Rack Mount 1 - 10 KVA Pure High Frequency online UPS with voltage adjustment 220
                                                                                    
                        
                        
                        
                                                            Rack Mount 1 - 10 KVA Pure High Frequency online UPS with voltage adjustment 220
                                                    
                        
                     6 - 10KVA 220V - 240V Uninterrupted Power Supply Online Pure Sine Wave High
                                                                                    
                        
                        
                        
                                                            6 - 10KVA 220V - 240V Uninterrupted Power Supply Online Pure Sine Wave High
                                                    
                        
                     1, 2, 3 KVA 220V - 240V AC High Frequency Online UPS with RS232, SNMP, USB / 8A
                                                                                    
                        
                        
                        
                                                            1, 2, 3 KVA 220V - 240V AC High Frequency Online UPS with RS232, SNMP, USB / 8A
                                                    
                        
                     10KVA / 8000W 110V UPS status with charging current value to computer
                                                                                    
                        
                        
                        
                                                            10KVA / 8000W 110V UPS status with charging current value to computer
                                                    
                        
                     12p / 6p, 160KVA Low Frequency Online 3 - Phase Uninterrupted Power Supply
                                                                                    
                        
                        
                        
                                                            12p / 6p, 160KVA Low Frequency Online 3 - Phase Uninterrupted Power Supply
                                                    
                        
                     Dual Conversion 120 - 800KVA Low Frequency Online UPS / Uninterrupted Power
                                                                                    
                        
                        
                        
                                                            Dual Conversion 120 - 800KVA Low Frequency Online UPS / Uninterrupted Power